Durable, Media-Isolated Pressure Sensor for Harsh Industrial Environments

Features

Wide pressure range: 1 bar to 70 bar (absolute), 8 bar to 70 bar (sealed gage)
Analog outputs: Ratiometric (0.5–4.5V), Regulated (various), Current (4–20mA)
Digital outputs: I2C and SPI with 24-bit resolution
Total Error Band (TEB) as low as ±0.75 %FSS across -40°C to 125°C
Industry-leading BFSL accuracy as low as ±0.15 %FSS
Stainless steel, hermetically welded construction—no internal seals
High insulation resistance >100 MΩ, dielectric strength at 1000 VDC
EMC protection: Radiated immunity up to 100 V/m, surge immunity ±1 kV
Miswiring, reverse voltage, and overvoltage protection up to ±40 VDC
Supports media such as water, refrigerants, oil, fuel, gas, and oxygen
Compliant with NSF/ANSI/CAN 61 (drinking water), UL, CE, UKCA, RoHS, REACH
Durable design for freeze-thaw cycles, vibration, and long-term use

Get Quote

Contact us for pricing and availability information.

Product Description

Honeywell MIP Series Pressure Sensors offer a heavy-duty, compact solution for accurate pressure measurement across a wide variety of media, including aggressive fluids and gases. Designed with stainless steel construction and hermetic sealing, the MIP Series provides analog and digital outputs, high EMC immunity, and a wide temperature range, making it suitable for industrial, HVAC/R, transportation, medical, and consumer applications.

Specifications

Brand:Honeywell
Series:MIP Series
Output Types:Ratiometric: 0.5–4.5 VDC, Regulated: 1–6 VDC, 0.25–10.25 VDC, 1–5 VDC, Current: 4–20 mA, Digital: SPI (50–1000 kHz), I2C (100–400 kHz)
Pressure Range:1 bar to 70 bar (absolute), 15 psi to 1000 psi (absolute), 8 bar to 70 bar (sealed gage), 100 psi to 1000 psi (sealed gage)
Accuracy:Up to ±0.15% FSS (BFSL)
Total Error Band:±0.75% to ±2.0% FSS (output dependent)
Operating Temperature:-40°C to 125°C
Material:Stainless Steel (Hermetically Welded)
Insulation Resistance:>100 MΩ at 1000 VDC
Certifications:NSF/ANSI/CAN 61, UL, CE, UKCA, RoHS, REACH
Protections:Reverse Voltage, Over Voltage ±40 VDC, Surge Immunity ±1 kV, Load Dump (ISO7637-2, ISO16750-2)
Applications:Industrial Pumps and Compressors, Water and Flow Control Systems, HVAC and Refrigeration Systems, Automotive and Transportation Equipment, Medical Gases and Hospital Equipment, Consumer Appliances and Sports Devices
Warranty:Manufacturer standard (varies by distributor)